ULC212A16A Busbars for UL489, 2 pole, 16sqmm

Ціна за запитом
The two pole busbar for UL489 devices has the phase sequence of L1, L2,... . The maximum operating voltage is 600V AC/DC and it has a max. current of 115A., eng

ULC212A18A Busbars for ULcut, 2 pole 18sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices has the phase sequence of L1, L2,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC212A25A Busbars for ULcut, 2 pole 25sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices has the phase sequence of L1, L2,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC218A16A Busbars for UL489, 2 pole, 16sqmm

Ціна за запитом
The two pole busbar for UL489 devices has the phase sequence of L1, L2,... . The maximum operating voltage is 600V AC/DC and it has a max. current of 115A., eng

ULC246A18H1PA Busbars for ULcut, 2 pole, 18sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC246A25H1PA Busbars for ULcut, 2 pole, 25sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC256A18A Busbars for ULcut, 2 pole 18sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices has the phase sequence of L1, L2,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC256A25A Busbars for ULcut, 2 pole 25sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices has the phase sequence of L1, L2,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC306A16A Busbars for UL489, 2 pole, 16sqmm

Ціна за запитом
The three pole busbar for UL489 devices has the phase sequence of L1, L2,L3,... . The maximum operating voltage is 600V AC/DC and it has a max. current of 115A., eng

ULC309A18H1PA Busbars for ULcut, 3 pole, 18sqmm

Ціна за запитом
The first cuttable three pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,L3,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC309A25H1PA Busbars for ULcut, 3 pole, 25sqmm

Ціна за запитом
The first cuttable three pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,L3,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC312A16A Busbars for UL489, 2 pole, 16sqmm

Ціна за запитом
The three pole busbar for UL489 devices has the phase sequence of L1, L2,L3,... . The maximum operating voltage is 600V AC/DC and it has a max. current of 115A., eng