ULC106A16A Busbars for UL489, 1 pole, 16sqmm
ULC112A16A Busbars for UL489, 1 pole, 16sqmm
ULC112A18A Busbars for ULcut, 1 pole 18sqmm
ULC112A25A Busbars for ULcut, 1 pole 25sqmm
The first cuttable one pole busbar for UL489 devices has the phase sequence of L1, L1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng
ULC118A16A Busbars for UL489, 1 pole, 16sqmm
ULC137A18H1FA Busbars for ULcut, 1 pole, 18sqmm
The first cuttable one pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng
ULC137A25H1FA Busbars for ULcut, 1 pole, 25sqmm
The first cuttable one pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng
ULC157A18A Busbars for ULcut, 1 pole 18sqmm
ULC157A25A Busbars for ULcut, 1 pole 25sqmm
The first cuttable one pole busbar for UL489 devices has the phase sequence of L1, L1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng
ULC206A16A Busbars for UL489, 2 pole, 16sqmm
ULC210A18H1PA Busbars for ULcut, 2 pole, 18sqmm
The first cuttable two pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng
ULC210A25H1PA Busbars for ULcut, 2 pole, 25sqmm
The first cuttable two pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng