ULC106A16A Busbars for UL489, 1 pole, 16sqmm

Ціна за запитом
The one pole busbar for UL489 devices has the phase sequence of L1, L1,... . The maximum operating voltage is 1000V AC/DC and it has a max. current of 115A., eng

ULC112A16A Busbars for UL489, 1 pole, 16sqmm

Ціна за запитом
The one pole busbar for UL489 devices has the phase sequence of L1, L1,... . The maximum operating voltage is 1000V AC/DC and it has a max. current of 115A., eng

ULC112A18A Busbars for ULcut, 1 pole 18sqmm

Ціна за запитом
The first cuttable one pole busbar for UL489 devices has the phase sequence of L1, L1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC112A25A Busbars for ULcut, 1 pole 25sqmm

Ціна за запитом
The first cuttable one pole busbar for UL489 devices has the phase sequence of L1, L1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC118A16A Busbars for UL489, 1 pole, 16sqmm

Ціна за запитом
The one pole busbar for UL489 devices has the phase sequence of L1, L1,... . The maximum operating voltage is 1000V AC/DC and it has a max. current of 115A., eng

ULC137A18H1FA Busbars for ULcut, 1 pole, 18sqmm

Ціна за запитом
The first cuttable one pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC137A25H1FA Busbars for ULcut, 1 pole, 25sqmm

Ціна за запитом
The first cuttable one pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC157A18A Busbars for ULcut, 1 pole 18sqmm

Ціна за запитом
The first cuttable one pole busbar for UL489 devices has the phase sequence of L1, L1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC157A25A Busbars for ULcut, 1 pole 25sqmm

Ціна за запитом
The first cuttable one pole busbar for UL489 devices has the phase sequence of L1, L1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng

ULC206A16A Busbars for UL489, 2 pole, 16sqmm

Ціна за запитом
The two pole busbar for UL489 devices has the phase sequence of L1, L2,... . The maximum operating voltage is 600V AC/DC and it has a max. current of 115A., eng

ULC210A18H1PA Busbars for ULcut, 2 pole, 18sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 80A (min. 16 sqmm / AWG 6) while feed-in in the middle there is a max. current of 160A (min. 50sqmm / AWG 1). , eng

ULC210A25H1PA Busbars for ULcut, 2 pole, 25sqmm

Ціна за запитом
The first cuttable two pole busbar for UL489 devices with auxiliary switch after each phase has the phase sequence of L1,L2,H1,... Depending on the position of the feed-in, on the beginning the busbar has a max. current of 100A (min. 25 sqmm / AWG 4) while feed-in in the middle there is a max. current of 200A (min. 2x 50sqmm / 2x AWG 1). , eng